{"id":71,"date":"2023-02-17T15:43:16","date_gmt":"2023-02-17T15:43:16","guid":{"rendered":"https:\/\/www.celec.gob.ec\/hidronacion\/?post_type=informacion-tecnica&#038;p=71"},"modified":"2023-06-27T16:08:15","modified_gmt":"2023-06-27T16:08:15","slug":"central-hidroelectrica-baba","status":"publish","type":"informacion-tecnica","link":"https:\/\/www.celec.gob.ec\/hidronacion\/informacion-tecnica\/central-hidroelectrica-baba\/","title":{"rendered":"Central Hidroel\u00e9ctrica BABA"},"content":{"rendered":"\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/06\/baba.jpg\" alt=\"\" class=\"wp-image-1466\" srcset=\"https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/06\/baba.jpg 1024w, https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/06\/baba-300x169.jpg 300w, https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/06\/baba-768x432.jpg 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<p>Informaci\u00f3n T\u00e9cnica<\/p>\n\n\n\n<div id=\"wp-block-themeisle-blocks-accordion-31a7c39b\" class=\"wp-block-themeisle-blocks-accordion exclusive\">\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Sala de Control<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\">\n<p><strong>SALA DE CONTROL (SISTEMA DE COMANDO, CONTROL Y PROTECCI\u00d3N)<\/strong><\/p>\n\n\n\n<p>Es un sistema que permite a los usuarios (Operadores de la Central) la Supervisi\u00f3n, Control, Monitoreo y Operaci\u00f3n, porque entre&nbsp; sus funcionalidades est\u00e1n las de:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Arranque y Paro de las Unidades,<\/li>\n\n\n\n<li>Adquisici\u00f3n y Procesamiento de datos,<\/li>\n\n\n\n<li>Control y Regulaci\u00f3n: Velocidad, Apertura, Potencia Activa, Limitador de Apertura, Potencia Reactiva, Factor de Potencia, Tensi\u00f3n,<\/li>\n\n\n\n<li>Supervisi\u00f3n, Operaci\u00f3n y Monitoreo de los equipos de la Planta, mediante el registro de: alarmas, eventos, gr\u00e1ficos y reportes.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"677\" height=\"471\" src=\"https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/02\/sala-de-control.png\" alt=\"\" class=\"wp-image-72\" srcset=\"https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/02\/sala-de-control.png 677w, https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/02\/sala-de-control-300x209.png 300w\" sizes=\"auto, (max-width: 677px) 100vw, 677px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>El software que se ha utilizado es el WINCC V6 SP2 que se soporta en la plataforma Windows 2000 o XP&nbsp; y mediante una adecuada programaci\u00f3n y usode sus bibliotecas y asistentes,se facilit\u00f3 la creaci\u00f3n de las pantallas gr\u00e1ficas y reportes, generaci\u00f3n de pantallas de alarmas y eventos, creaci\u00f3n de archivos, curvas de datos del proceso, etc. La interface gr\u00e1fica, la r\u00e1pida actualizaci\u00f3n de las im\u00e1genes y el banco de datos garantizan elevada disponibilidad y calidad al sistema.<\/p>\n\n\n\n<p>El Sistema Digital de Supervisi\u00f3n y Control de la Central Baba tiene los siguientes niveles de automatizaci\u00f3n:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Nivel 0.-&nbsp;<\/strong>Operaci\u00f3n a nivel de proceso, acciones ejecutadas \u201ca pie de equipo\u201d.<\/li>\n\n\n\n<li><strong>Nivel 1.-&nbsp;<\/strong>Operaci\u00f3n ejecutada desde las interfaces hombre-m\u00e1quina (HMI, por sus siglas en ingl\u00e9s) o botoneras de los tableros de control de los diferentes subsistemas.<\/li>\n\n\n\n<li><strong>Nivel 2.-&nbsp;<\/strong>Operaci\u00f3n realizada desde las estaciones de operaci\u00f3n e ingenier\u00eda ubicadas en la Sala de Control.<\/li>\n<\/ul>\n\n\n\n<p>En cuanto al hardware del sistema, mencionaremos los componentes principales:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Estaciones de operaci\u00f3n, supervisi\u00f3n e ingenier\u00eda compuesta por computadoras tipo PC, ubicadas en la Sala de Control,<\/li>\n\n\n\n<li>Impresora para impresi\u00f3n de alarmas y eventos,<\/li>\n\n\n\n<li>Sistema de Comando y Control, compuesto por los paneles:\n<ul class=\"wp-block-list\">\n<li>Control de la Unidad Generadora 1 (PCG1);<\/li>\n\n\n\n<li>Control de la Unidad Generadora 2 (PCG2);<\/li>\n\n\n\n<li>Control de los Servicios Auxiliares, Sincronismo, L\u00ednea Corta de 230kV y Transformadores de 51 MVA&nbsp; (PCS);<\/li>\n\n\n\n<li>Comando, Control y Protecci\u00f3n de la Subestaci\u00f3n (PRS).<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<\/div><\/details>\n\n\n\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Subestaci\u00f3n<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\">\n<p><strong>Subestaci\u00f3n Elevadora 13,8\/230 kV<\/strong><\/p>\n\n\n\n<p>El esquema de la subestaci\u00f3n elevadora es de barra simple y sin acoplamiento.<\/p>\n\n\n\n<p>Los equipos que forman parte de la subestaci\u00f3n elevadora ubicada en el nivel 95.20 msnm, son los siguientes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dos (2) Transformadores de potencia, 13,8\/230KV, 37\/51MVA;<\/li>\n\n\n\n<li>Dos (2) Seccionadores de apertura horizontal de 242 kV, 1.600 A, accionamiento motorizado, sin cuchillas de puesta a tierra;<\/li>\n\n\n\n<li>Seis (6) Pararrayos de 192 kV, 10 kA.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"449\" src=\"https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/02\/SUBESTACION-1.png\" alt=\"\" class=\"wp-image-74\" srcset=\"https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/02\/SUBESTACION-1.png 640w, https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/02\/SUBESTACION-1-300x210.png 300w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>TRANSFORMADORES ELEVADORES<\/strong><\/td><\/tr><tr><td>Tipo:<\/td><td><strong>Trif\u00e1sico, 2 bobinados<\/strong><\/td><\/tr><tr><td>Potencia continua en todas las posiciones del cambiador de tomas (MVA):<\/td><td>37\/51<\/td><\/tr><tr><td>Eficiencia m\u00ednima nominal:<\/td><td>0,995<\/td><\/tr><tr><td>Tipo de instalaci\u00f3n:<\/td><td>A cielo abierto<\/td><\/tr><tr><td>Tipo de refrigeraci\u00f3n:<\/td><td>ONAN\/ONAF<\/td><\/tr><tr><td>Voltaje nominal lado BT (kV):<\/td><td>13,8<\/td><\/tr><tr><td>Voltaje nominal lado AT (kV):<\/td><td>230 \u00b12&#215;2,5 %<\/td><\/tr><tr><td>Frecuencia nominal (Hz):<\/td><td>60<\/td><\/tr><tr><td>Tipo de cambiador de taps (derivaciones) en lado AT:<\/td><td>Sin carga<\/td><\/tr><tr><td>M\u00e9todo de puesta a tierra lado AT:<\/td><td>S\u00f3lidamente aterrizado<\/td><\/tr><tr><td>Terminal de neutro en lado AT:<\/td><td>S\u00ed<\/td><\/tr><tr><td>Nivel de aislamiento:<\/td><td>Lado AT<\/td><td>Lado BT<\/td><\/tr><tr><td>&nbsp;&nbsp; Tensi\u00f3n soportable al impulso atmosf\u00e9rico BIL (kVp)<\/td><td>950<\/td><td>110<\/td><\/tr><tr><td>&nbsp;&nbsp; Tensi\u00f3n soportable a la maniobra (kVp)<\/td><td>750<\/td><td>&nbsp;<\/td><\/tr><tr><td>&nbsp;&nbsp; Nivel de aislamiento a 60 Hz, 1 min. (kVrms)<\/td><td>460<\/td><td>34<\/td><\/tr><tr><td>Grupo vectorial:<\/td><td>YNd1<\/td><\/tr><tr><td>Elevaci\u00f3n de temperatura sobre el ambiente a 40<sup>o<\/sup>C:<\/td><\/tr><tr><td>&nbsp;&nbsp; Del aceite en la parte superior medida con term\u00f3metro (\u00b0C)<\/td><td>55<\/td><\/tr><tr><td>&nbsp;&nbsp; En el bobinado medido por imagen t\u00e9rmica (\u00b0C)<\/td><td>55<\/td><\/tr><tr><td><strong>&nbsp;<\/strong><\/td><\/tr><tr><td><strong>Seccionadores sin cuchillas de puesta a tierra<\/strong><\/td><\/tr><tr><td>Tipo\/Montaje:<\/td><td><strong>Motorizado\/Horizontal<\/strong><\/td><\/tr><tr><td>Apertura:<\/td><td>Central<\/td><\/tr><tr><td>Tensi\u00f3n nominal (valor eficaz kV):<\/td><td>245<\/td><\/tr><tr><td>Tensi\u00f3n soportable nominal al impulso por rayo 1,2&#215;50 \u03bcs (valor pico kV):<\/td><td>950<\/td><\/tr><tr><td>Tensi\u00f3n soportable nominal a frecuencia industrial 1 min (valor eficaz kV):<\/td><td>395<\/td><\/tr><tr><td>Frecuencia nominal (Hz):<\/td><td>60<\/td><\/tr><tr><td>Corriente nominal (valor eficaz):<\/td><td>1.600 A<\/td><\/tr><tr><td>Corriente soportable de corta duraci\u00f3n 1s (valor eficaz):<\/td><td>31,5 kA<\/td><\/tr><tr><td>Corriente soportable moment\u00e1nea (valor pico):<\/td><td>50 kA<\/td><\/tr><tr><td>Tiempo de apertura:<\/td><td>8,4 s<\/td><\/tr><tr><td>Tiempo de cierre:<\/td><td>8,1 s<\/td><\/tr><tr><td><strong>&nbsp;<\/strong><\/td><\/tr><tr><td><strong>Pararrayos<\/strong><\/td><\/tr><tr><td>Tipo:<\/td><td><strong>&nbsp;Oxido zinc<\/strong><\/td><\/tr><tr><td>Voltaje nominal (Kv- rms):<\/td><td>192<\/td><\/tr><tr><td>Voltaje m\u00e1ximo de operaci\u00f3n continua-MCO (Kv-rms):<\/td><td>154<\/td><\/tr><tr><td>Corriente de descarga (kA):<\/td><td>10<\/td><\/tr><tr><td>Frecuencia nominal (Hz):<\/td><td>60<\/td><\/tr><tr><td>Capacidad t\u00e9rmica (kJ):<\/td><td>7,8<\/td><\/tr><tr><td>Nivel de aislamiento a frecuencia industrial (Kv-rms):<\/td><td>395<\/td><\/tr><tr><td>Nivel de aislamiento de impulso atmosf\u00e9rico (Kv-pico):<\/td><td>950<\/td><\/tr><tr><td>Distancia m\u00ednima de contorneo (mm):<\/td><td>7.250<\/td><\/tr><tr><td>Tensi\u00f3n residual a corriente de impulso 10kA-8&#215;20\u03bcs (kV-pico):<\/td><td>452<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\"><strong>TABLA: CARACTER\u00cdSTICAS DE LOS EQUIPOS DE LA S\/E<\/strong><\/figcaption><\/figure>\n<\/div><\/details>\n\n\n\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Video Central Baba<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-video\"><video height=\"360\" style=\"aspect-ratio: 492 \/ 360;\" width=\"492\" controls src=\"https:\/\/www.celec.gob.ec\/hidronacion\/wp-content\/uploads\/2023\/02\/Proyecto-Baba.mp4\"><\/video><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/details>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Informaci\u00f3n T\u00e9cnica<\/p>\n","protected":false},"author":3,"featured_media":0,"template":"","meta":{"_acf_changed":false,"_themeisle_gutenberg_block_has_review":false},"class_list":["post-71","informacion-tecnica","type-informacion-tecnica","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.celec.gob.ec\/hidronacion\/wp-json\/wp\/v2\/informacion-tecnica\/71","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.celec.gob.ec\/hidronacion\/wp-json\/wp\/v2\/informacion-tecnica"}],"about":[{"href":"https:\/\/www.celec.gob.ec\/hidronacion\/wp-json\/wp\/v2\/types\/informacion-tecnica"}],"author":[{"embeddable":true,"href":"https:\/\/www.celec.gob.ec\/hidronacion\/wp-json\/wp\/v2\/users\/3"}],"wp:attachment":[{"href":"https:\/\/www.celec.gob.ec\/hidronacion\/wp-json\/wp\/v2\/media?parent=71"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}